Security
Standards |
|
Achievable |
|
| |
DOD Unified Facilities
Criteria (UFC) Standards |
|
 |
| |
GSA/ISC
Level IV Standards |
|
 |
| |
GSA/ISC Level V
Standards |
|
 |
|
|
Perimeter
Security/Standoff Distances |
|
Achievable |
|
| |
Secure
and controlled perimeter
greater than 100 feet |
|
 |
| |
100
feet stand-off area from
public roadways, existing
adjacent buildings |
|
 |
| |
Perimeter
barriers capable of stopping
vehicles
(landscaping, bollards, trenches, walls) |
|
 |
|
|
Structural/Architectural
Design |
|
Achievable |
|
| |
Progressive
collapse avoidance |
|
 |
| |
Blast
resistance |
|
 |
| |
Glazing
of windows and doors |
|
 |
| |
Loading
docks, receiving and shipping
areas: 50 feet from utility
rooms, mains, lobbies |
|
 |
| |
Loading
docks, receiving and shipping
areas:
enhanced with blast proof walls |
|
 |
| |
Stairwells
do not discharge into lobbies,
loading
docks, or mail room ares |
|
 |
| |
No
building overhangs |
|
 |
|
|
Mechanical/Electrical/Plumbing
Design |
|
Achievable |
|
| |
New building air in-takes on 4th floor or higher |
|
 |
| |
Utilities
installed and distributed
so as to mitigate
damage due to explosion |
|
 |
| |
Intrusion
detection systems |
|
 |
| |
Interior
water supply looped and
sectionalized |
|
 |
| |
Redundant
communication systems |
|
 |
| |
Significant
distance between emergency
and normal
electric panels, conduits, and switchgear |
|
 |
| |
Mailroom
areas contain separate,
dedicated air
ventilation and exhaust systems |
|
 |
| |
Emergency
air distribution shutoff |
|
 |
| |
Mass
notification system |
|
 |
|
|
Parking
and Vehicular Access |
|
Achievable |
|
| |
Control
of parking facilities and
access roads |
|
 |
| |
Vehicular
inspection points and parking
outside 100 feet stand-off
area |
|
 |
| |
Drive-up/drop-off
areas outside stand-off
distances |
|
 |
|
|
Entry/Interior
Security |
|
Achievable |
|
| |
Employee
and visitor identification
procedures |
|
 |
| |
Visitor
control/screening area
outside 100 feet
stand-off area |
|
 |
| |
X-ray,
man-gates, and magnetometers
at public access points |
|
 |
| |
Access
control to utility/roof
areas |
|
 |
| |
Compliance
with NFPA 101 fire life
safety standards |
|
 |
| |
Emergency
power to critical systems
(fire protection, alarm
systems, computing, etc.) |
|
 |
| |
Established
occupant emergency plans |
|
 |
| |
Signage
advising of security procedures |
|
 |
| |
CCTV
monitoring with sufficient
lighting at
entrances/circulation areas |
|
 |
|
|
Unobstructed
Space |
|
Achievable |
|
| |
Unobstructed
space within 10 meters
of buildings
(concealment) |
|
 |
| |
Trash
containers (outside 25
meters, hardened trash
enclosures, or secured
access) |
|
 |
| |
Electrical
and mechanical equipment
on roof |
|
 |
|
|
|
|
|