Security
Standards | Perimeter
Security/Standoff Distances | Structural/Architectural
Design | Mechanical/Electrical/Plumbing
Design | Parking
and Vehicular Access | Entry/Interior
Security | Unobstructed
Space
|
Security
Standards |
|
Achievable |
|
| |
DOD
Unified Facilities Criteria (UFC)
Standards |
|
 |
| |
GSA/ISC
Level IV Standards |
|
 |
| |
GSA/ISC
Level V Standards |
|
 |
|
| back to top
|
|
Perimeter
Security/Standoff Distances |
|
Achievable |
|
| |
Secure
and controlled perimeter greater
than 100 feet |
|
 |
| |
100
feet stand-off area from public
roadways, existing adjacent buildings |
|
 |
| |
Perimeter
barriers capable of stopping vehicles
(landscaping, bollards, trenches,
walls) |
|
 |
|
| back to top
|
|
Structural/Architectural
Design |
|
Achievable |
|
| |
Progressive
collapse avoidance |
|
 |
| |
Blast
resistance |
|
 |
| |
Glazing
of windows and doors |
|
 |
| |
Loading docks,
receiving and shipping areas: 50
feet from utility rooms, mains,
lobbies |
|
 |
| |
Loading docks,
receiving and shipping areas:
enhanced with blast proof walls |
|
 |
| |
Stairwells
do not discharge into lobbies,
loading
docks, or mail room ares |
|
 |
| |
No building
overhangs |
|
 |
|
| back to top
|
|
Mechanical/Electrical/Plumbing
Design |
|
Achievable |
|
| |
New
building air in-takes on 4th floor
or higher |
|
 |
| |
Utilities
installed and distributed so as
to mitigate
damage due to explosion |
|
 |
| |
Intrusion
detection systems |
|
 |
| |
Interior water
supply looped and sectionalized |
|
 |
| |
Redundant communication
systems |
|
 |
| |
Significant
distance between emergency and
normal
electric panels, conduits, and
switchgear |
|
 |
| |
Mailroom areas
contain separate, dedicated air
ventilation and exhaust systems |
|
 |
| |
Emergency air
distribution shutoff |
|
 |
| |
Mass notification
system |
|
 |
|
| back to top
|
|
Parking
and Vehicular Access |
|
Achievable |
|
| |
Control
of parking facilities and access
roads |
|
 |
| |
Vehicular
inspection points and parking outside
100 feet stand-off area |
|
 |
| |
Drive-up/drop-off
areas outside stand-off distances |
|
 |
|
| back to top
|
|
Entry/Interior
Security |
|
Achievable |
|
| |
Employee
and visitor identification procedures |
|
 |
| |
Visitor
control/screening area outside
100 feet
stand-off area |
|
 |
| |
X-ray,
man-gates, and magnetometers at
public access points |
|
 |
| |
Access control
to utility/roof areas |
|
 |
| |
Compliance
with NFPA 101 fire life safety
standards |
|
 |
| |
Emergency power
to critical systems (fire protection,
alarm systems, computing, etc.) |
|
 |
| |
Established
occupant emergency plans |
|
 |
| |
Signage advising
of security procedures |
|
 |
| |
CCTV monitoring
with sufficient lighting at
entrances/circulation areas |
|
 |
|
| back to top |
|
Unobstructed
Space |
|
Achievable |
|
| |
Unobstructed
space within 10 meters of buildings
(concealment) |
|
 |
| |
Trash
containers (outside 25 meters,
hardened trash enclosures, or secured
access) |
|
 |
| |
Electrical
and mechanical equipment on roof |
|
 |
|
|
|
|
|